MOXUS Metabolic System

 

 

Precision Performance in Exercise & Resting Metabolic Testing.  

Accurate, reliable data every time.

 

Benefits:

·       The most stable and repeatable respirometry components:

·       S-3A/I Oxygen Analyzer

·       CD-3A Carbon Dioxide Analyzer

·       KTC3 Turbine Volumetric System

·       Fast 100-millisecond response time Analyzers for accurate breath-by-breath measurements.

·       Modular system for ease of validating data manually and teaching.

·       Allows for use with Douglas bags for system validation and analysis.

·       Very flexible software features: Plot variables are user selectable; print various reports and graphs; breath-by-breath or averaged-breath analysis; edit reports; export to spreadsheet; and many more.

·       User defined analog inputs.

·       Very rugged, heavy-duty cart includes a supplies drawer and an articulating arm.

·       Worldwide reputation for excellence in quality and service.

 

Standard Features

·       S-3A/I Oxygen Analyzer

·       CD-3A Carbon Dioxide Analyzer

·       Turbine Volume Measurement System

·       Pump and Flow Controller

·       Windows Software and Interface Package

·       Heart Rate Interface with Polar monitor

·       4.2 Liter Active Mixing Chamber

·       Efficient Nafion-based desiccant box with molecular sieve & silica gel indicator

·       Two-Way Breathing Valve and Tubing Connections with Headgear and Mouthpieces

·       Front panel Calibration Port for easier calibration

·       Heavy-Duty MOXUS Cart with supplies drawer and articulating support arm

·       Computer (2GHz or greater), 17” Flatpanel Monitor, and Color Ink Jet Printer

 

Optional Features

·       System setup, calibration, and training at your facility

·       MOXUS Software and Interface Box available for users with their own analyzers

·       System minus computer and/or cart – lower cost and lower shipping charges

 

Specifications

Specifications for S-3A/I Oxygen Analyzer:

Speed of Response: To 90% of final value in less than 100 milliseconds for a step change in oxygen concentration; achieved without electronic anticipation circuitry. The lag or transport time (time needed for sample to travel from source to sensor), and possible mixing of sample gas front, will be greater with increase in sample line length and diameter, and with decrease in flow rate.

Accuracy: ±0.01% O2 on the percent oxygen scale, within working range

Working Range: Calibration gas value ±5% of full scale value

Stability: ±0.01% oxygen in 24 hours with constant temperature and pressure

Sensitivity: ±0.001% oxygen

Resolution: Digital Display: ±0.01 on each scale

Analog Outputs: Buffered output for 0-100% O2;

Ambient Temperature: 0-40°C

Sensor Tubing Connections: (IN/OUT) 1/8|0.071 inch o.d. stainless steel 

Sample Flow Rate: 10-300 ml/min, 250 ml/min recommended for most applications

 

Specifications for CD-3A Carbon Dioxide Analyzer:

Speed of Response: To 90% of final value in less than 100 milliseconds for a step change in carbon dioxide concentration; the lag or transport time (time needed for sample to travel from source to sensor), and possible mixing of sample gas front, will be greater with increase in sample line length and diameter, and with decrease in flow rate.

Accuracy: ±0.02% carbon dioxide or 1% of the reading, whichever is larger

Sensitivity: ±0.01% carbon dioxide

Resolution: Digital Display: ±0.01% carbon dioxide

Range: 0-15% carbon dioxide

Display: Continuous display of CO2 concentration or End Tidal for each breath

Analog Output: Buffered 0 to 15% CO2

Sample Flow Rate: 10-1000 ml/min

Stability: ±0.02% carbon dioxide at 5% in 8 hours maximum drift

Sensor Tubing Connections: (IN/OUT) 1/8 / 1/8 inch o.d. stainless steel

 

Specifications for the TurbineVolumetric Module KTC3D:

 

ELECTRONIC VOLUMETRIC MODULE KTC3D

FLOW RANGE: 0.05 - 16.50 L/sec (3.0 - 1000 L/min), see the Flow Transducer specifications.

VOLUME RANGE: Unlimited.

RESPIRATION RATE: 0 - 150 Breaths/minute.

ACCURACY: 3% (Typically less than 1%).

STABILITY: Short and long term, 100%.

WARM-UP TIME: None.

PICK-UP ASSEMBLY K520 (shockproof, nonimmersible)

PICK-UP METHOD: Infrared, optically focused.

CONNECTOR: Three-pin DIN

TURBINE CARTRIDGE C521_(shockproof, immersible, sterilizable):

FLOW RANGE: 0.02 to 20.0 Liters/second (1.2 to 1200 Liters/minute).

LINEAR RANGE: 0.05 to 16.5 Liters/second.

REPEATIBILITY: 0.3 %

RESISTANCE: 1.3 cm H2O per Liter/second @ 12 Liters/second.

DEAD SPACE: 25 ml.

INPUT PORT: 31 mm OD (1.225” - 1.250") taper.

OUTPUT PORT: 30 mm OD (1.165") cylinder.

STERILIZATION: Liquid chemical method, Sidex or similar.

CARTRIDGE EXCHANGE: The cartridge is instantly removable for sterilization or replacement without reca­libration. Cartridges are cali­brated and identical within 0.7 %.

 

MOXUS Modular Metabolic System Testimonial

October 24, 2000

 (905) 525-9140 x24465
E-mail: phillis@mcmaster.ca

Mr. Henry Ginsberg
AEI Technologies
300 William Pitt Way
Pittsburgh, Pennsylvania 15238

Dear Mr. H. Ginsberg and J. Veltre:

I am writing this letter to let you know that since purchasing your Moxus metabolic cart 8 months ago we have been extremely happy with the performance of this product. Our decision to purchase and AEI system was based on my and my co-worker's past experience with a number of other metabolic carts including the Physiodyne Max-1 cart, Vacumed systems, and various Sensormedics systems. I can honestly say that based on my past experience and my current experience, your system has outperfomed all of the aforementioned systems in the areas of both reproducibility and accuracy (when compared with Douglas bags) of ventilation, V02, and VCO2.

Interestingly, in a recent comparison (using 6 subjects) of both the peak and steady-state VO2, VCO2, and ventilation values and we obtained from a set of AEI's old (both more than 15 years) oxygen and carbon dioxide analyzers the values were within 3±1% of that obtained with the new Moxus cart. This level of stability is no doubt enviable amongst your competitors.

Moreover, I would like to add that the level of service and courtesy that we have received from your company has been over and above that received from both Physiodyne and Sensormedics. I would go so far as to say that your professional and accommodating attitude eclipses that of your competitors! In short, please feel free to use me as a reference for people who may be considering purchasing your system. I would be happy to tell them what a tremendous and highly reliable product you have and what great service you offer.

I wish you continued success at AEI; however, I suspect that with continued service such as you now offer along with solid products I suspect that success will not be a problem.

Sincerely,

Stuart M. Phillips, Ph.D.

Assistant Professor, McMaster University